Spearlab Cryogenic Foam Dewars蛋白结晶试剂盒Hampton Research

Hampton Research蛋白结晶试剂盒

Spearlab Cryogenic Foam Dewars
Spearlab Cryogenic Foam Dewars

Spearlab Cryogenic Foam Dewars

Spearlab Cryogenic Foam Dewars

Spearlab Cryogenic Foam Dewars

Spearlab Cryogenic Foam Dewars

Products > Cryocrystallography > Dewars > Spearlab Cryogenic Foam Dewars

Spearlab Cryogenic Foam Dewars

Applications

  • Cryocrystallography

Features

  • Each dewar is supplied with a lid
  • Proprietary foam construction (USPTO # 7,971,744)
  • Mini (130 ml), Small (500 ml), Standard (800 ml), Large (1400 ml) and Tall (1800 ml)
  • Reduced ice formation on dewar lip
  • Easier to dry
  • Foam construction reduces slipping

Description

Spearlab FD-130 Cryogenic Foam Dewar (130 ml) – Mini : Small, hexagonal outside, hand held foam dewar, maximum volume 175 ml. Each dewar is supplied with a matching foam lid to insulate the contents from ambient air. Dimensions of the cylindrical cavity in this vessel are 2 inches in diameter by 3.5 inches deep, so that it easily holds 130 ml and a maximum volume of 175 ml of liquid nitrogen. The HR4-676 has an overall height of approximately 4.5 inches without cover and the width is 3.5 inches at the top and 3.75 inches on the bottom (measured on the flats of the hexagon). Circular cover is approximately 0.5 inches tall x 3.5 inches diameter.

Spearlab Cryogenic Foam Dewar (500 ml) – Small: The small foam dewar shape is circular, with a protruding handle, so that it resembles a large teardrop. Each dewar is supplied with a matching foam lid to insulate the contents from ambient air. Dimensions of the cylindrical cavity in this vessel are 4.5 inches in diameter by 2.8 inches deep, so that it easily holds 500 ml of liquid nitrogen.

Spearlab FD-800 Cryogenic Foam Dewar (800 ml) – Standard: The standard foam dewar shape is circular, with a protruding handle, so that it resembles a large teardrop. Each dewar is supplied with a matching foam lid to insulate the contents from ambient air. Dimensions of the cylindrical cavity in this vessel are 5.8 inches in diameter by 2.8 inches deep, so that it easily holds 800 ml of liquid nitrogen.

Spearlab FD-1400 Cryogenic Foam Dewar (1400 ml) – Large: The large foam dewar shape is circular, with a protruding handle, so that it resembles a large teardrop. Each dewar is supplied with a matching foam lid to insulate the contents from ambient air. Dimensions of the cylindrical cavity in this vessel are 6.3 inches in diameter by 3.8 inches deep, so that it easily holds 1400 ml of liquid nitrogen. Overall height is approximately 6 inches without cover and the width is 9 inches on the short axis and 11 inches on the long axis. Cover approximately 0.5 inches tall x 9 inches diameter.

Spearlab FD-1800 Cryogenic Foam Dewar (1800 ml) – Tall: The tall foam dewar shape is a tapered octagon on the outside with a cylindrical interior. The tapered octagon features a wide, stable base. Each dewar is supplied with a matching foam lid to insulate the contents from ambient air. Dimensions of the cylindrical cavity in this vessel are 3.5 inches in diameter by 12.5 inches deep, so that it holds approximately 1,800 ml of liquid nitrogen. The outside dimensions of the tall dewar are 15.25 inches tall with a 6.25 inches wide top and a 7.75 inches wide base (measured on the flats of the octagon). The cover is 6.5 inches in diameter and 0.5 inches thick.

The patented (USPTO # 7,971,744) design of the Spearlab Cryogenic Foam Dewar makes it easy to handle and safer to use than a traditional low profile glass dewar. Also, because of its lower thermal mass, a foam vessel will cause less boil off when it is filled with liquid nitrogen. Additionally, the dewar will accumulate less frost during regular use. The end result is that less liquid nitrogen is consumed.

The dewars are made from cross-linked polyethylene foam. A density of 4 pounds per cubic foot is used for the 130 ml and 800 ml dewars. A density of 2 pounds per foot is used for the 1400 ml and 2 liter dewars. The higher density foam has significantly higher mechanical strength and stiffness. The lower density foam has slightly lower thermal conductivity. Like most lightweight insulation materials, the thermal conductivity of the foam is predominantly determined by the thermal conductivity of air, which eventually permeates the pores of the foam material.

Show More



Spearlab Cryogenic Foam Dewars

Click to Zoom In

Spearlab Cryogenic Foam Dewars

Spearlab Cryogenic Foam Dewars

Click to Zoom In

Spearlab Cryogenic Foam Dewars

CAT NO

HR4-676

NAME

Cryogenic Foam Dewar (130 ml) – Mini

DESCRIPTION

each

PRICE

$51.00

cart quote

CAT NO

HR4-662

NAME

Cryogenic Foam Dewar (500 ml) – Small

DESCRIPTION

each

PRICE

$87.00

cart quote

CAT NO

HR4-673

NAME

Cryogenic Foam Dewar (800 ml) – Standard

DESCRIPTION

each

PRICE

$102.00

cart quote

CAT NO

HR4-674

NAME

Cryogenic Foam Dewar (1400 ml) – Large

DESCRIPTION

each

PRICE

$163.00

cart quote

CAT NO

HR4-675

NAME

Cryogenic Foam Dewar (2 liter) – Tall

DESCRIPTION

each

PRICE

$184.00

cart quote

Support Material(s)

Spearlab Cryogenic Foam Dewars Spearlab Cryogenic Foam Dewars

Hampton Research, first in crystallization since 1991, developing and delivering crystallization and optimization screens, reagents, plates, and other tools for the crystallization of biological macromolecules, including proteins (antibody), peptides (insulin), and nucleic acids (DNA).

  • Products
  • |

  • Gallery
  • |

  • My Account
  • |

  • Contact Us
  • |

  • Quick Order
  • Support
  • Privacy Policy
  • |

  • Terms and Conditions
  • Products
  • |

  • Gallery
  • |

  • My Account
  • |

  • Support
  • |

  • Contact Us
  • |

  • Quick Order
  • |

  • Privacy Policy
  • |

  • Terms and Conditions
© 2021 HAMPTON RESEARCH CORP.


| Website by Skyhound Internet