Airmodus A10 Particle Size Magnifier
全球最好的1nm级检测仪器!
- 商品编号:Airmodus A10 Particle Size Magnifier
- 货 号:Airmodus A10 Particle Size Magnifier
- 品 牌:Airmodus(对我们而言,关键的价值在于帮助用户改进其气溶胶测量解决方案。我们想提升超细亚微米颗粒的知识和意识。 我们开始作为科学仪器的制造商,但气溶胶颗粒不仅仅是科学界的兴趣。 因此,我们进一步发展了我们系统的可用性和多功能性,以满足工业用户的需求。 我们的技术团队具有气溶胶测量的坚实背景,我们都在为您服务。)
- 计量单位:台
- 市场价: ¥0.00
- 销售价: 面议
购买数量: |
|
- 收藏此商品
See the smallest particles!
Study and monitor particles smaller than the detection threshold of any CPC. Airmodus Particle Size Magnifier A10 grows nano sized aerosol particles into sizes that can be detected with a standard CPC. Particles as small as 1 nm can be counted.
For a complete nanoparticle counting system
– an nCNC system – please ask for the Airmodus A11. The A11 combines the A10 PSM with the Airmodus A20 CPC and an easy to use operating software
Benefits of the A10
– Detect particles as small as
1 nm in diameter in real time
– Also the electrically neutral particles
– Detect nucleation in-situ as it happens
– Study the formation and growth of 1-4 nm particles
– Use the activation spectrum for information of size or composition of the sampled particles
Three operation modes
– Fixed mode: One fixed cut-off* for monitoring the appearance of nanoparticles.
– Stepping mode: Steps through several user-defined cut-offs*. Use to observe pre-defined size classes.
– Scanning mode: scans through the operation range in less than 5 minutes, giving the activation spectrum of 1 – 4 nm* particles
The A10 PSM is calibrated with nickel chromium nanoparticles. Based on the calibration, you can easily adjust your system for a particular nickel chromium equivalent cut-off diameter using the PSM management software. The possible equivalent 50% cut-off diameters range from 1 to 4 nm.
Measurement range 1 – 1000 nm.
50% cut-off selectable: 1.2 – 3.5 nm*
Aerosol sample flow 2.5 lpm
Sample flow to CPC 1 – 1.5 lpm. Other flows possible. Please contact for details.
Working fluid Diethylene Glycol (>99%)
Sample conditions
Pressure: 90 to 105 kPa
Relative humidity: 0 to 95% non-condensing**
Environmental conditions
Temperature: 15oC to 30oC Pressure: 90 to 105 kPa
Relative humidity: 0 to 95% non-condensing
Communication Serial: RS-232
USB: type B connector
Analog out: BNC connector 0 to 10 V for external devices, e.g. controlling of a DMA or ion filter.
All communication based on ASCII character-encoding scheme.
Fittings External vacuum: fitting for 1/4 in. tubing External compressed air: fitting for 1/4 in. tubing Inlet: 1/4 in. stainless steel tube
Outlet: 1/4 in. stainless steel tube
Software Airmodus A1X software for online data inversion and data acquisition (for Microsoft Windows).
Note: Online data inversion only when used with an Airmodus CPC.
External vacuum requirement
100 – 350 mbar pressure at NTP
External compressed air requirement
1.5 – 2.5 bar at NTP
The air should be free of particles, oil and water (dew point below 0oC); maximum operating pressure is 3.0 bar at NTP.
Power requirements 100 – 240 VAC
max. 320 W
universal AC input/full range
Concentration Depends on the particle counter used with the PSM. PSM has minor losses inside it and dilutes the sample depending on the saturator flow rate used. The PSM software takes the dilution into account, and the concentration data saved by the program is corrected for it.
Dimensions and weight
290x450x465 (height x width x depth in mm)
17.0 kg
Shipping conditions Temperature: 0 – 40oC
Relative humidity: <95% non condensing
The instrument should be shipped in upright position and should be protected against tremor and blows.
*) Nickel chromium equivalent activation diameter
**) Above 40% please dry the sample to avoid excess water condensation inside the instrument
Microsoft and Windows are registered trademarks of Microsoft Corporation.