AP-LITE-TURB 水体浊度计价格|型号 _浊度测定仪原理


AP-LITE-TURB 水体浊度计

AP-LITE-TURB 水体浊度计

  • 商品编号:AP-LITE-TURB 水体浊度计
  • 货  号:AP-LITE-TURB 水体浊度计
  • 计量单位:
  • 所得积分:260
  • 市场价: ¥31200.00
  • 销售价: ¥26000.00
  • 节省: ¥5200.00
购买数量:
  (库存9999+)

  • 收藏此商品

app hook

AP-LITE-TURB 水体浊度计

 

内置GPS,无需手动记录地点信息,数据可导入Google地图 ‘’AP-LITE-TURB浊度荧光计由Aquameter读数表、AP-LITE传感器罩以及LITE-TURB浊度传感器三个主要部分组成,用于测量水体浊度,系统可通过GPS Aquameter现场读取和采集数据。

技术参数:

Aquameter读数表:

尺寸(W*H*D):90*180*39mm

重量(含电池):450g

显示屏:带背光,80个字符LCD

内存:1900个数据

GPS:内置天线,12通道,精度±10m

大气压:150mb-1150mb,精度1mb

供电:5*AA碱性或可充电Ni-MH电池

操作温度:-20~70 ˚C

防护等级:IP67

AP-LITE传感器罩:

直径:24mm

长度:250mm

浊度传感器:

测量范围:0 – 3000 NTU

分辨率:2个自动调节的量程: 0.0–99.9 NTU, 100 – 3000 NTU

重复性:读数的± 2%

注:其中浊度传感器可更换为其他光学传感器(叶绿素,淡水蓝绿藻类,海洋蓝绿藻类,若丹明,成品油,CDOM)形成相对应的荧光计。

Standard Parameters  
Dissolved Oxygen Range 0 – 500.0% / 0 – 50.00 mg/L
Resolution 0.1% / 0.01mg/L
Accuracy 0 – 200%: ± 1% of reading. 200% – 500%: ± 10%
Conductivity (EC) Range 0 – 200 mS/cm (0 – 200,000 µS/cm)
Resolution 3 Auto-range scales: 0 – 9999 µS/cm, 10.00 – 99.99 mS/cm, 100.0 – 200.0mS/cm
Accuracy ± 1% of reading
TDS* Range 0 – 100,000 mg/L (ppm)
Resolution 2 Auto-range scales: 0 – 9999mg/L, 10.00 – 100.00g/L
Accuracy ± 1% of reading
Resistivity* Range 5 Ωcm – 1 MΩcm
Resolution 2 Auto-range scales: 5 – 9999 Ωcm, 10.0 – 1000.0 KΩcm
Accuracy ± 1% of reading
Salinity* Range 0 – 70 PSU / 0 – 70.00 ppt (g/Kg)
Resolution 0.01 PSU / 0.01 ppt
Accuracy ± 1% of reading
Seawater Specific Gravity* Range 0 – 50 st
Resolution 0.1 st
Accuracy ± 1.0 st
pH Range 0 – 14 pH / ± 625mV
Resolution 0.01 pH / ± 0.1mV
Accuracy ± 0.1 pH / ± 5mV
ORP Range ± 2000mV
Resolution 0.1mV
Accuracy ± 5mV
Temperature Range -5°C – +50°C (23°F – 122°F)
Resolution 0.01° C/F
Accuracy ± 0.5° C
Optional Parameters  
Depth ** Range 0-60m (AP-2000 & AP-5000), 0 – 100m (AP-7000)
Resolution 0.01m
Accuracy ±0.5% FS (AP-2000 & AP-5000), ±0.2%FS (AP-7000)
**Option on the AP-2000. Comes as standard on the AP-5000 & AP-7000
Ion Specific Electrodes***  
Ammonium Range 0 – 9,000mg/L (ppm)
Resolution 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 9,000 mg/L
Accuracy ± 10% of reading
Ammonia† Range 0 – 9,000mg/L (ppm)
Resolution 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 9,000 mg/L
Accuracy ± 10% of reading
Chloride Range 0 – 20,000mg/L (ppm)
Resolution 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 20,000 mg/L
Accuracy ± 10% of reading
Flouride Range 0 – 1,000mg/L (ppm)
Resolution 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 999.9 mg/L
Accuracy ± 10% of reading
Nitrate Range 0 – 30,000mg/L (ppm)
Resolution 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 30,000 mg/L
Accuracy ± 10% of reading
Calcium Range 0 – 2,000mg/L (ppm)
Resolution 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 2,000 mg/L
Accuracy ± 10% of reading
† Ammonium electrode required. Readings calculated from Ammonium, pH and temperature electrode values.
Optical Electrodes***  
Turbidity Range 0 – 3000 NTU
Resolution 2 Auto-range scales: 0.0 99.9 NTU, 100 – 3000 NTU
Repeatability ± 2% of reading
Chlorophyll Range 0 – 500 µg/L (ppb)
Resolution 0.01 µg/L
Repeatability ± 2% of reading
Phycocyanin (Freshwater Blue-Green Algae) Range 0 – 300,000 cells/mL
Resolution 1 cell/mL
Repeatability ± 2% of reading
Phycoerythrin (Marine Blue-Green Algae) Range 0 – 200,000 cells/mL
Resolution 1 cell/mL
Repeatability ± 2% of reading
Rhodamine WT Dye Range 0 – 500 µg/L (ppb)
Resolution 0.01 µg/L
Repeatability ± 5% of reading
Fluorescein Dye Range 0 – 500 µg/L (ppb)
Resolution 0.01 µg/L
Repeatability ± 5% of reading
Refined Oil Range 0 – 10,000 µg/L (ppb)
Resolution 0.1 µg/L
Repeatability ± 2% of reading
CDOM/FDOM Range 0 – 2,000mg/L (ppm)
Resolution 2 Auto-range scales:
0.00 – 99.99 mg/L, 100.0 – 2,000mg/L
Repeatability ± 10% of reading or 2ppm (whichever is greate